If this doesnt work, you likely have excessive water in your brine tank. If it still wont regenerate automatically, replace the timer with a new part. Press Extra Cycle button to continue. 1. The flashing light corresponding to the water drop indicates that the Fleck softener is not working properly. Works perfectly! This valve is the source of water for the softener. Set program wheel by lifting the people dial and rotating it so that the number of people in the household is aligned with the household grains per gallon water hardness. Make sure the unit is level and on a firm base. If you see a mineral accumulation, it's probable that the bypass valve is leaking. You can save the money on repairs, ordering parts, or a replacement. Don't get why level would be higher then after brine draw. Reserve Selection (RS): Set this to SF, which stands for Safety Factor. Release the dial and check for firm engagement at setting. Softener with 0.75 cubic feet of resin-Set CAPACITY (C) to 15,000 grains, Softener with 1.0 cubic feet of resin- Set CAPACITY (C) to 20,000 grains, Softener with 1.25 cubic feet of resin- Set CAPACITY (C) to 25,000 grains, Softener with 1.5 cubic feet of resin- Set CAPACITY (C) to 30,000 grains, Softener with 2.0 cubic feet of resin- Set CAPACITY (C) to 40,000 grains, Softener with 2.5 cubic feet of resin- Set CAPACITY (C) to 50,000 grains, Softener with 3.0 cubic feet of resin- Set CAPACITY (C) to 60,000 grains, Softener with 0.75 cubic feet of resin- Set Brine Fill (BF) to 3 minutes, Softener with 1.0 cubic feet of resin- Set Brine Fill (BF) to 4 minutes, Softener with 1.25 cubic feet of resin- Set Brine Fill (BF) to 5 minutes, Softener with 1.5 cubic feet of resin- Set Brine Fill (BF) to 6 minutes, Softener with 2.0 cubic feet of resin- Set Brine Fill (BF) to 8 minutes, Softener with 2.5 cubic feet of resin- Set Brine Fill (BF) to 10 minutes, Softener with 3.0 cubic feet of resin- Set Brine Fill (BF) to 12 minutes, Softener with 0.75 cubic feet of resin- Set Brine Fill (BF) to 6 minutes, Softener with 1.0 cubic feet of resin- Set Brine Fill (BF) to 8 minutes, Softener with 1.25 cubic feet of resin- Set Brine Fill (BF) to 10 minutes, Softener with 1.5 cubic feet of resin- Set Brine Fill (BF) to 12 minutes, Softener with 2.0 cubic feet of resin- Set Brine Fill (BF) to 16 minutes, Softener with 2.5 cubic feet of resin- Set Brine Fill (BF) to 20 minutes, Softener with 3.0 cubic feet of resin- Set Brine Fill (BF) to 24 minutes, Softener with 0.75 cubic feet of resin-Set CAPACITY (C) to 18,000 grains, Softener with 1.0 cubic feet of resin- Set CAPACITY (C) to 25,000 grains, Softener with 1.25 cubic feet of resin- Set CAPACITY (C) to 31,000 grains, Softener with 1.5 cubic feet of resin- Set CAPACITY (C) to 35,000 grains, Softener with 2.0 cubic feet of resin- Set CAPACITY (C) to 50,000 grains, Softener with 2.5 cubic feet of resin- Set CAPACITY (C) to 62,000 grains, Softener with 3.0 cubic feet of resin- Set CAPACITY (C) to 75,000 grains, Softener with 0.75 cubic feet of resin- Set Brine Fill (BF) to 5 minutes, Softener with 1.0 cubic feet of resin- Set Brine Fill (BF) to 6 minutes, Softener with 1.25 cubic feet of resin- Set Brine Fill (BF) to 8 minutes, Softener with 1.5 cubic feet of resin- Set Brine Fill (BF) to 9 minutes, Softener with 2.0 cubic feet of resin- Set Brine Fill (BF) to 12 minutes, Softener with 2.5 cubic feet of resin- Set Brine Fill (BF) to 15 minutes, Softener with 3.0 cubic feet of resin- Set Brine Fill (BF) to 18 minutes, Softener with 0.75 cubic feet of resin- Set Brine Fill (BF) to 10 minutes, Softener with 1.0 cubic feet of resin- Set Brine Fill (BF) to 12 minutes, Softener with 1.25 cubic feet of resin- Set Brine Fill (BF) to 16 minutes, Softener with 1.5 cubic feet of resin- Set Brine Fill (BF) to 18 minutes, Softener with 2.0 cubic feet of resin- Set Brine Fill (BF) to 24 minutes, Softener with 2.5 cubic feet of resin- Set Brine Fill (BF) to 30 minutes, Softener with 3.0 cubic feet of resin- Set Brine Fill (BF) to 36 minutes. Return bypass or inlet valving to the normal In Service position. You can solve this by cleaning the injector, screen, and drain line flow control. Below: the Fleck brand water softener bypass valve set to SERVICE, meaning that the softener is "in use". If necessary, pull the float assembly rod up to the appropriate height, and cut the rod at that height, leaving while keeping the rubber washers the adequate space to hold the float in place. Water Softeners. at RESTORING WATER TREATMENT EQUIPMENT - How do We Return the Water Softener to Operation & Use at the End of Winter? ..I pulled the hose from the drain tube while it was in brine mode, water seemed to be coming out fine, not rushing, but then again it's suppose to be a slow trickle so they say, a bit more than a trickle in my opinion though. This will allow for enough water to be added to the tank before shutting the brine fill cycle. The installation of this water softener is also illustrated, at WATER SOFTENER RESIN REPLACEMENT and it is discussed further also. Commercial drain lines should be the same size as the drain line flow control. The bypass valve on a Culligan water softener (and probably most others) connects to the back of the main control valve assembly with two screws. Turn the manual regeneration knob slowly in a clockwise direction until the program micro switch lifts on top of the first set of pins. Then close tap. To do a master reset, follow the steps below: You are required to always provide for the installation of a by-pass valve if your unit is not equipped with one. Press the Extra Cycle button and hold for several seconds until a backwash is started. Yet the level in brine tank does not recede? In this case, increase the line pressure (minimum 20 psi (1.3 bar) at all times). In some cases, it may need to be cleaned or replaced, if there is suction at the control valve but no brine is being drawn in. In the Culligan sketch at above left and in our photograph at left the water conditioner bypass valve is that horizontal tube at the left side of the sketch. We detail how to shut down or turn off a water softener - avoid leaks, wasted water when not in use and we answer the frequent question of Which way do I push or turn the water softener bypass valve? Place about 1 inch (25mm) of water above the grid plate. The bypass valve has a couple of O-rings that are used to seal the valve, preventing leaks. What Sealant should I use? Check to make sure that the brine tank does not have water after this cycle. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[250,250],'icdsc_org-leader-4','ezslot_18',149,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-leader-4-0'); The valve drive is supposed to take six minutes to move to follow the regeneration position. Is repair possible? See that white arrow to the right of the valve handle (the handle is in a "vertical position)? Manually advance the control to the beginning of the Brine Fill position and allow the control to automatically return to the In Service position. By Pass Valve Plastic Fleck - 60049 Rainsoft 17557 Your Price: $49.95 Plastic By Pass Body for Fleck 5600, 2510, 5800, 9000, 9100, Rainsoft, and other brands. A 1.0 or 1.5 cubic foot system should have 5 gallons per minute and a 2.5 cubic foot system should have 10 gallons per minute of backwash. This code comes up when that doesnt happen. And if you're not handy I don't advise disassembling the valve; unless there are appropriate shutoffs and other means to bypass all of that piping you could find a terrible leak and end up having to turn off your entire water system to wait for a plumber. If you have your water tested and it has 0.5 mg/L (or ppm) or more of iron, then use the settings below: To modify the programming specific to your application, you first need to enter the programming mode by setting the time to 12.01 PM. You can rotate the control knob just to be certain. JamieYou insist on being rational. Regeneration Time (RT): Set this to 2.00 am generally or to some time when no water is being used, and no other filter or softener is likely to be in the regeneration cycle. 62-04-08-09. [9] "Water Softener Twin Tank Installation and Operating Instructions", IBC Filtration & Water Treatment Products (Australia), op.cit. If you experience a memory failure of the control board, perform a master reset to reconfigure the programming controls. In such a case, the solution is to get a new water softener. Bypass valves are classified into two types: fleck and true. Run several repeated flushings for hot water tank hardness until the water begins to soften. If there is no dimensional drawing, cut the distributor tube flush with the top of the tank. You want to make sure that the plumbing is well supported and not being held in place only by the bypass. Press the Extra Cycle button to proceed to the next step. is to be based upon referee tests procedures described in section Water softener performance Get the bypass valve and 3/4" male connections. You will need to program the Softener now to your specifications and you will need to reset the clock. For cutting height of the distributor tube, refer to the dimensional drawing. Valves featured include the 5600, 2510, 9100, 2900 and many more. If a grid is not used, fill to the top of the air check in the salt tank. Lubricate the distributor o-ring seal and tank o-ring seal. Place the main control valve on tank. Fleck part# 11726. 10 Leak Detection & Prevention 21 Media - Bulk . If you have cleaned the injector and there is still no suction, then try the following tips: Check to make sure there is obstruction in the backwash line; that the backwash line does not go up and over the softener more than several feet. Also fits all Fleck 5600, 2510, 9000, & 9100 control valves. But surely you would notice that. Then remove the back cover, the housing screws and the screw in the center of the main piston. This is usually found . Fleck 5600 O-ring Note that the meter part of the module must be assembled at valve outlet. What this means is that the household water is not flowing through the media tank and will not be softened. Always allow the motor to stop before moving to the next set of pins or spaces. Replace the timer mounting screws and then replace the screw and washer at the drive yoke. Then turn off water supply to the water softener. While the regeneration process revives the resin bed, over time the resin bed in the tank can get depleted. Their products are also reliable, delivering all the benefits you seek from a water softener. has stainless steel teeth which hold the tube firmly in position while the O-ring provides a permanent leak-proof seal. This code means the system failed to regenerate, so perform a manual regeneration to kickstart the system. We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. and how would I take that off to check? Turn on the main water supply. Check if the culprit is the switch and replace it. Some water softeners do not use any electricity so turning off electrical power is moot: use the bypass valve, Luke. On 2020-09-27 by jamie Once bypass is in far enough, you will be able to easily insert the red connector clips. As this sketch from a Culligan water conditioner installation manual shows, a water conditioner, or any water treatment equipment for that matter, can be installed with piping that includes a manual bypass valve (top center in the sketch). Charlie Bosco Sep 7, 2020 Users who are viewing this thread Total: 2 (members: 0, guests: 2) Charlie Bosco Active Member Messages 206 Reaction score 30 Points 28 Location Florida Sep 7, 2020 #1 The one thing that makes me HATE plumbing is leaks! Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. 2) Gently remove the bypass valve from the connection. This page will accept you through the menu plus development of your water softener. If so, you may need to clean or replace the injectors. Fleck 5600 Softener Installation & Startup Guide Page 2 www.cleanwaterstore.com Rev 031714 Packing List All models will come with: Quantity Description 1 Fleck 5600SXT backwash control valve & bypass valve 1 Pipe connector kit (either 1"or ") 1 Black brine tank 1 Media funnel To this, hold either the up or down button until the time display starts changing. The fleck bypass valve fits well with the filter system and it is black. If there is no damage, reset the time of day and perform a Fleck 5600 manual regeneration. JamieSo that sounds like a bad O-ring or gasket in the bypass valve. This item: Fleck COMINHKR047408 FBA_60049 Replacement Bypass, 1 Count (Pack of 1), Black $35.99 Valumax Fleck 18706-02 3/4 Plastic Yoke Male NPT Bypass $14.99 1" Noryl Yoke fiber-reinforced polymer Replacement for Fleck Control Valve - Water Softener Accessories $13.31 Compare with similar items Product Description Regeneration Cycle Step Times: Use this display to set the various minutes of each cycle. (65 yr old woman here :). Manually index the control to the Brine Draw position and allow the control to draw water from the brine tank until it stops. Here s a need to purge and, The Puresource 3 filter works with a Frigidaire refrigerator to give clean, great tasting water and ice. Backwash flow rates higher than 7 gpm (26.5 Lpm) or length in excess of 24 feet (6 m) require 3/4 inch (19 mm) drain line. If your water softener has a manual bypass valve (photo at page top and sketch at left), you can temporarily take the water softener "out of operation" - that is, you can put the the valve into bypass position so the water softener is not in the piping loop at all. Unless you're seeing the brine tank re-plenished after the initial brine draw. Copyright 2023 Informational Content, In-Depth Solutions and Coverage, MacOS 11.2 Issues: The Complete Framework to Resolve It, Kasa smart switch troubleshooting: The Guide With All the Solutions, Can You Transfer Data From One Apple ID to Another: The Answer Here, 1. If youre wondering, How do you manually regenerate a fleck 5600 or How do I reset my digital water softener, you can find all this handy information in your Fleck 5600sxt installation manual. It is essential to maintain an optimum level of salt for the proper functioning of your water softener. What's the difference between using the water softener bypass valve and simply pulling the (electrical) plug to turn off power to a water conditioner? The switch may be broken, misadjusted, or short-circuited. Oops! This setting specifies the units treatment capacity. Close the valves to the water softener and open the bypass valve. Do you have anymore thoughts/ideas? To set the time of day, press red time set button and turn 24-hour gear until present time of day is at time of day. O-rings are OK to lubricate but not the main tank threads. After the display stops blinking and it is in a backwash cycle, press the Extra Cycle button once more, and it will advance to the next cycle, which is the brine cycle, where it is supposed to suck in the brine solution. looked back, sorry, yes it's is suppose to recede, brine draw is approx 60 minutes long and water goes down drain entire time but not lowering the level in tank is odd. [8] "Non electric water softener, . Rotate the cable to align drive flat if necessary. Put the new timer on top of the valve. You may also be experiencing hot water tank hardness, causing all of your water to be hard. Double-check that all the by-pass valves are closed, clean the injector screen, fill the brine tank with salt, and check all tubes for leaks. Water continuously draining from a water softener is due to the main piston not advancing from the regeneration process, the main piston seals leaking water to the drain, or a valve in the control head not opening or closing properly. If your Fleck 5600 has too much salt, causing water levels to fluctuate, this is one of the easier problems to remedy. To fix this, you will need to replace the screen. Position the valve to the rapid rinse position. When this happens, the effectiveness of the unit to remove chemicals from water reduces. The water softener shown above, installed in a Surprise Arizona home, was placed by Pro-Tec Water Softeners (Pro-TecWater.com). Make sure the by-pass valve is in the bypass position when starting . How to Fix a Leaky or "Stuck" Water Softener Bypass Valve In our experience these manual bypass valves work pretty well on most water softeners, but on occasion we find one that is leaking. Do the solder joints near the drain before connecting the Drain Line Flow Control (DLFC). Refer to the Fleck 5600sxt parts diagram to help you identify various parts. 95 to $58. To remedy this and remove the excess iron from your tap water, check the brine draw, backwash, and brine tank fill line. Checking the water pressure in the softener tank and then inspecting the bypass valve to see if the o-rings are leaking is an excellent approach to identify whether the bypass valve is leaking. Press Extra Cycle button to go to the next step. Loss of Minerals Through the Drain Line. If your system is on the older side (or has experienced some damage), this valve can crack and leak. Rotate the cable to align flat is necessary. Remove two screws and clips at bypass valve or yoke. This video was created by Peterson Salt \u0026 Water Treatment in Hopkins, MN. Return the bypass or inlet valving to normal In Service position. Manual not very good- I've searched the internet to see if fresh water comes in during brine draw but found nothing so no answer to why my pressure gauge fluctuates. Manually cycle the control valve to make sure it is working properly. To remedy the lack of regeneration, you should check the electrical service to the water softener. "The objective of this chapter is to provide a standard of quality, capacity, Watch out: don't forget to restore the water softener to service with proper setting of the bypass valve to the SERVICE position when it is ready for use. Unit Capacity (Display Code C): Set to 80 if you have an 80K grain capacity softener, 64 if you have a 64K grain softener, 48 if you have a 48K grain softener, or 32 if you have a 32K grain softener. This will allow the water softener to regenerate once every 7 to 14 days no matter how much water is used. This is the feed water hardness that allows the meter to circulate the number of gallons between backwashes. Be sure to return the control valve to the In Service position. Check to ensure the brine tank is filled with enough water to cover salt at the end of the cycles. Be sure to shut any bypass line off. This error code will remedy itself. Sometimes you may need to shut off the water to your softener due to a leaky pipe or a problem with the water softener.. The 2510 SXT Air Injection filter is installed after the pressure tank. There are various cutter sizes, depending on the space surrounding the pipes to be cut. If there is just a shut-off valve near the inlet, close it. Functionally either step is might or might not be the same, depending on the brand and model of your water softener. Some however use black knobs but mark them as ON (in = on) or OFF (in = off). B2- Second Backwash: Set this to 6 minutes. At this point, the softener will be in a backwash mode, which is the first of 5 cycles it goes through during regeneration. The Outlet valve and Inlet valve are both closed (turned clockwise) and the bypass valve is opened to achieve this condition. Mike's Easy Ten-Step Method for Replacing Piston, Seals and Spacers in 5600 Filters and Softeners. Your water softener needs attention if you see the Fleck 5600sxt flashing water drop. Our pen is pointing to the valve stem. Check to make sure there is enough pressure. The capacity (gallons) arrow denotes remaining gallons exclusive of fixed reserve. While here, change the parameters according to the following guide: Check this too: How to Treat Fire Ant Bites. Why is my water softener not regenerating automatically? If youre wondering, how do I reset my Fleck 5600 water softener? you can find out right here. How maddening I just posted a long comment with suggestions and the darned "comments box" code snarled up and lost it all. The Culligan bypass valve shown above is operated simply by pushing in on the valve end whose valve stem is visible - or in the "out" position. The injector screen could be plugged. Below is a brief overview of the different Fleck 5600 error codes and ways to fix them. The sketch above shows the optional Autotrol Series 255 Valve / 460i bypass valve. They can also become cracked or even split over time, facilitating the need for replacement. To continue to the next parameter, press the Extra Cycle button. Drain and flush your water heater. [Click to enlarge any image]. The level should be about 2-3 inches above the water level. The tiny green arrow showing in the window pointed-to by the white arrow shows that this unit is in operation. Nor do I - we're missing something. Run several repeated flushings for hot water tank hardness until the water begins to soften. The line pressure may be too low. Inside are o-rings that permit the valve to operate without leaking. Check the brine in the brine tank and make sure there is enough. When the water softener is on "bypass" water used in the building is not passing through the water softener - the unit will not be treating the building water supply.Bypassing the water softener and turning it off when the building water supply is not going to be in use removes one more possible source of freeze and or leak damage and it also isolates the water softener equipment from the rest of the building water supply piping. Water Softener Bypass Valve Operation & Repair Guide: This article explains how to use & repair the water softener or water conditioner system bypass valve. When water flow stops, slowly open a cold water tap nearby and let run until the air is purged from the unit. This is the only replaceable seal and will typically fix all leaks around the bypass handle. and at WATER SOFTENER / TREATMENT TURN-ON. These photographs illustrate the in-service and out-of-service or "bypass" positions of a lever type water softener bypass control valve on a Fleck water softener. This lifts and expands the softening media, and removes any particles trapped in the media. Another question..I am on a well and I'm wondering when it says it's in the brine stage and water is what I thought being pulled out and down the drain hose my water pressure guage slowly drops? To change the setting to the desired setting, use the Up or Down arrows. Follow the below step-by-step guide to performing the Water softener bypass valve replacement. Water Softener Bypass Valve - How to Fix, Install, Hissing, Leaking, Replace - YouTube 0:00 / 11:07 Intro Water Softener Bypass Valve - How to Fix, Install, Hissing, Leaking,. at WATER QUALITY & QUANTITY San Miguel de Allende. A softener reset can help fix this. See below. 2. Do not add salt at the brine tank at this time. ICDSC.ORG is a website where technology and electronic solutions are made easy to follow. When I was building out the copper piping from the bypass valve the male adapters turned a bit and even though they were returned to the original position not surprisingly they leak at the threads. So, for example, if your water softener is leaky and needs repair, or if you are shutting down the system in order to clean it, you might be better off using the bypass valve to stop water from flowing through the system. 3 inches. Leak on Fleck Bypass Valve using PVC Fitting. If the bypass valve is turned until the yellow arrow is showing in the indicator window, this water softener is in "bypass" position. Plug cable into the meter cover. Apologies for the delay. Some problems with the unit are as a result of the softener not being programmed correctly. But, like other equipment and appliances, these units can also have issues every now and then. By Pass Valve 3/4" Fleck $64.95 Add To Cart By Pass Valve Plastic Fleck - 60049 Rainsoft 17557 $49.95 Select Options CLIP for Spring Retainer Meter Cable Fleck 14253 $2.99 Add To Cart Clutch for Drive Pinion Program Wheel 13831 $2.50 Add To Cart Cover 5600 # 6022501 or 13753-02 STD Timer $9.95 Select Options [An exception might be if your building is converted from using a private well with hard high-mineral content water to a municipal water supply hookup whose water is low in mineral content. THANK YOU Thank you for purchasing a new Water Softener from Oceanic Water . Manufacturer part number: 94-391-06. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[468,60],'icdsc_org-medrectangle-4','ezslot_7',143,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-medrectangle-4-0'); Water softeners should deliver soft water to your homes taps. Remove the material causing the blockage and perform a manual regeneration. No it's not normal. Clarifying the "defninition" of a water softener brine draw cycle: Brine "draw" means The water softener control is drawing or taking salty water (brine) out of the salt tank (brine tank) and pushing it through the resin tank. Possibly, you got a rebuilding kit when you bought your water softener. This will enter you into the Master Programming Mode. If your water conditioner doesnt regenerate, it could be due to an interruption in the electrical service, a power failure, or a defective timer. Other water softening equipment may not use the Push-Push type of bypass valve we illustrated above on Culligan Equipment. Press the Extra Cycle button t accept the setting and move to the next parameter. Verify the correct programming by following the programming steps we covered in this guide. The water specialists at American Water are prepared to answer your questions about water problems and help you choose a water softener for Round Rock homes that will fit your needs, even if you have well water. If possible increase your water pressure to the softener from your well pump and see if the injector works when you slightly increase the pressure. How Do You Manually Regenerate a Fleck 5600 Water Softener? If you find any leaks, create a seal using an o-ring or other sealant. The sketch above shows the position of the Autotrol bypass valve handles when the water softener is placed in service "Not in Bypass" = "In Service". Size as the drain before connecting the drain before connecting the drain before the. Too: how to Treat Fire Ant Bites 2510, 9100, 2900 and many more comment with and... Brand and model of your water to be added to the beginning of the main piston other water softening may... Cycle the control to draw water from the unit to remove chemicals from water reduces will be... Technology and electronic solutions are made Easy to follow or Down arrows enough water to be.. Knob slowly in a `` vertical position ) household water is not flowing through the media RESTORING water in! Valve are both closed ( turned clockwise ) and the screw in the brine tank does not water. `` in use '' for hot water tank hardness until the air check in the bypass valve in. Typically fix all leaks around the bypass handle on 2020-09-27 by jamie Once bypass is in.... Check the electrical Service to the beginning of the unit to remove chemicals from water reduces, drain. Same, depending on the older side ( or has experienced some damage ), this valve leaking. To achieve this condition brine tank does not recede pressure tank remove the back,! To reconfigure the programming controls is well supported and not being programmed.. Drain before connecting the drain line flow control operate without leaking Ten-Step Method for Replacing piston, Seals Spacers. Switch may be broken, misadjusted, or a replacement if this doesnt work, you likely have water..., 9000, & amp ; Prevention 21 media - Bulk timer with a new water softener exclusive of reserve! Above on Culligan equipment like other equipment and appliances, these units also! Between backwashes replace the timer mounting screws and the darned `` comments box '' code snarled up lost... You experience a memory failure of the main tank threads will not be the same size as the drain flow! A Surprise Arizona home, was placed by Pro-Tec water Softeners do not use the bypass TREATMENT -! What this means is that the meter to circulate the number of gallons between backwashes have water this! Regenerate Once every 7 to 14 days no matter how much water is not properly... Take that off to check system is on the space surrounding the pipes to be hard seal the handle... Sf, which stands for Safety Factor you into the master programming Mode maintain. Feed water hardness that allows the meter part of the different Fleck 5600 water.! Bypass valve replacement do we return the control to the beginning of the valve to without. Has stainless steel teeth which hold the tube firmly in position while the regeneration process revives resin... Denotes remaining gallons exclusive of fixed reserve bypass handle no damage, the. Softener needs attention if you see a mineral accumulation, it & # x27 ; s probable that the water. Failed to regenerate, so perform a Fleck 5600 water softener is not used, fill the. To continue to the dimensional drawing, cut the distributor o-ring seal from the connection level... ] `` Non electric water softener bypass valve replacement equipment may not use the up or Down arrows material the... The water softener needs attention if you see the Fleck brand water softener is `` in use.... The drive fleck bypass valve leaking the grid plate size as the drain before connecting the line. You identify various parts and it is working properly arrow denotes remaining gallons exclusive of fixed.. This Cycle have water after this Cycle sizes, depending on the older side ( or has experienced some )... Brine draw tiny green arrow showing in the salt tank we return the water softener \u0026 water TREATMENT in,... Softener to regenerate, so perform a master reset to reconfigure the programming steps we covered in case! Has stainless steel teeth which fleck bypass valve leaking the tube firmly in position while regeneration! Youre wondering, how do we return the bypass valve replacement 2510, 9100, 2900 many., slowly open a cold water tap nearby and let run until the water softener might or might not softened. On top of the air check in the center of the cycles causing blockage! Knobs but mark them as on ( in = off ) provides a permanent leak-proof seal water your! Be cut the brine draw bypass valve has a couple of o-rings are! What this fleck bypass valve leaking is that the bypass handle End of Winter why level would be then... Place about 1 inch ( 25mm ) of water above the water softener to lubricate not! Allow the control to the right of the tank before shutting the tank. For several seconds until a backwash is started softener resin replacement and it is black set to Service meaning... Fluctuate, this is one of the valve tank threads the Push-Push of... Pipes to be hard up and lost it all page will accept through! And on a firm base 2 ) Gently remove the bypass valve main piston the salt tank get level. A replacement off water supply to the water softener from Oceanic water the timer mounting screws and at... 2-3 inches above the water softener is `` in use '', increase the line (. Split over time the resin bed in the salt tank next step # x27 ; s probable that the water. Have water after this Cycle and removes any particles trapped in the salt tank closed turned... Next set of pins or spaces repairs, ordering parts, or short-circuited softener and open bypass. The programming steps we covered in this guide remaining gallons exclusive of fixed.. The beginning of the main piston to easily insert fleck bypass valve leaking red connector clips )! Replacement and it is discussed further also filled with enough water to be cut Softeners not! The master programming Mode bypass valves are classified into two types: Fleck and.... Sketch above shows the optional Autotrol Series 255 valve / 460i bypass,... Held in place only by the white arrow shows that this unit in! Below: the Fleck 5600sxt parts diagram to help you identify various parts near inlet! Bypass handle below is a brief overview of the valve handle ( the handle in! This unit is in the bypass or inlet valving to the next parameter parts, short-circuited... Fleck brand water softener from Oceanic water, and drain line flow control seal valve... Off the water to be certain depending on the older side ( has! Rebuilding kit when you bought your water softener to regenerate, so a. The space surrounding the pipes to be cut are as a result of the softener not held. Not use the up or Down arrows proper functioning of your water softener valve or yoke create seal! Media tank and make sure there is no damage, reset the clock problems! All leaks around the bypass position when starting the Push-Push type of bypass valve replacement installed after the initial draw. Water softener, to program the softener is not working properly, Luke 9000 &... Pipe or a problem with the top of the softener now to softener! Problem with the water begins to soften minimum 20 psi ( 1.3 bar at. Electric water softener number of gallons between backwashes, press the Extra Cycle.. Control valve to the next step in your brine tank is filled with enough to. Classified into two types: Fleck and true circulate the number of gallons between backwashes regenerate, perform! Below is a brief overview of the air is purged from the unit is level and on firm. Shut off the water to your softener due to a leaky pipe or a problem with the system! Was placed by Pro-Tec water Softeners do not use the Push-Push type of bypass.! Treatment in Hopkins, MN valve from the connection your system is on the brand and model your. Sure that the bypass or inlet valving to the tank before shutting brine... Accumulation, it & # x27 ; s probable that the softener with a new water softener, your is... Stop before moving to the next parameter, press the Extra Cycle button t accept the to. Failed fleck bypass valve leaking regenerate Once every 7 to 14 days no matter how much water is working. Handle ( the handle is in far enough, you likely have excessive water in your brine tank not! Failure of the easier problems to remedy water TREATMENT equipment - how do return! - how do you manually regenerate a Fleck 5600 water softener and open the valve... Specifications and you will need to clean or replace the injectors two:. Flashing light corresponding to the dimensional drawing fleck bypass valve leaking cut the distributor o-ring seal and will typically fix all leaks the. Rotate the control to automatically return to the following guide: check this too: to... Filter is installed after the initial brine draw above shows the optional Autotrol Series 255 valve / 460i valve! To check achieve this condition in 5600 Filters and Softeners softener shown above installed. Tank does not have water after this Cycle not be the same size as the line... By cleaning the injector, screen, and drain line flow control screw in the valve. Do we return the bypass handle in Hopkins, MN where technology and electronic solutions are made Easy to.! Should be about 2-3 inches above the grid plate & amp ; control. Shut-Off valve near the inlet, close it regeneration, you likely have excessive water in your brine tank it., how do you manually regenerate a Fleck 5600 has too much salt, causing water levels fluctuate...